Emission Analyzer - Gas Analyzer | VEA 401/ 501 | DaTo Tech

EMISSION ANALYSER – VEA 401/ 501

Quick Overview

Description

The VEA-501/401 Gas Analyzer is for measuring CO, HC and CO2 in automotive emissions by the principle of non-dividing infrared absorption, measuring NO (Not for VEA-401)and O2 by the principle of electrochemical cell, calculating excessive air coefficient based on the composition of CO, CO2, HC and O2 measured. It is an intellectual instrument with LCD display and English interface. Inductive RPM (engine-speed) measuring pliers, oil temperature sensor and printer are optional for measuring RPM and oil temperature, and printing measurement results.

This instrument complies with the requirements of International Measurement Rules OIML R99/1998 (E) made by the Organization of International Measurement Law (OIML) and the National Metrological Verification Regulations # JJG 688 for class-1 instruments. It is applicable for environmental departments, vehicle inspection stations, automotive manufacturing factories and garages.

VEA501

VEA401

Details

Specifications

Operation Condition

 

Resolution

 

Temperature

+5 to +40

HC 

1ppm

Relative humidity

5to 95non-condensing

CO

0.01%

Atmospheric pressure

70 KPa to 106 KPa

CO2

0.01%

Power supply

 

O2

0.01%

Voltage

AC110V±15

NO (Not for NHA-406)

1ppm

Frequency

60Hz ±1Hz

RPM

10rpm

Measurement Range

 

Oil Temperature

1

HC (Hexane Equivalent)

0ppm to 10000ppm

Indication Error

Absolute Relative

CO

0% to 10%

HC (0ppm to 2000ppm)

±12 ppm ±5%

CO2

0% to 20%

(2001ppm to 10000ppm)

" -- ±10%

O2

0% to 25%

CO

±0.06% ±5%

NO (Not for VEA 401)

0ppm to 5000ppm

CO2

±0.5% ±5%

RPM

300rpm to 8000rpm

O2

±0.1% ±5%

Oil Temperature

0 to +120

NO (Not for NHA-406)

±25ppm ±4%

Others

Warm-up Time

10 minutes

Outer Dimension

(L)450mm(W)260mm(H)180mm

Output Interface

RS-232C

Net Weight

7kg