EMISSION ANALYSER – VEA 401/ 501

Description

The VEA-501/401 Gas Analyzer is for measuring CO, HC and CO2 in automotive emissions by the principle of non-dividing infrared absorption, measuring NO (Not for VEA-401)and O2 by the principle of electrochemical cell, calculating excessive air coefficient based on the composition of CO, CO2, HC and O2 measured. It is an intellectual instrument with LCD display and English interface. Inductive RPM (engine-speed) measuring pliers, oil temperature sensor and printer are optional for measuring RPM and oil temperature, and printing measurement results.

This instrument complies with the requirements of International Measurement Rules OIML R99/1998 (E) made by the Organization of International Measurement Law (OIML) and the National Metrological Verification Regulations # JJG 688 for class-1 instruments. It is applicable for environmental departments, vehicle inspection stations, automotive manufacturing factories and garages.

CATALOGUE

Specifications

Operation Condition Resolution
Temperature +5 to +40 HC  1ppm
Relative humidity 5to 95non-condensing CO 0.01%
Atmospheric pressure 70 KPa to 106 KPa CO2 0.01%
Power supply O2 0.01%
Voltage AC110V±15 NO (Not for NHA-406) 1ppm
Frequency 60Hz ±1Hz RPM 10rpm
Measurement Range Oil Temperature 1
HC (Hexane Equivalent) 0ppm to 10000ppm Indication Error Absolute Relative
CO 0% to 10% HC (0ppm to 2000ppm) ±12 ppm ±5%
CO2 0% to 20% (2001ppm to 10000ppm) ” — ±10%
O2 0% to 25% CO ±0.06% ±5%
NO (Not for VEA 401) 0ppm to 5000ppm CO2 ±0.5% ±5%
RPM 300rpm to 8000rpm O2 ±0.1% ±5%
Oil Temperature 0 to +120 NO (Not for NHA-406) ±25ppm ±4%
Others
Warm-up Time 10 minutes Outer Dimension (L)450mm(W)260mm(H)180mm
Output Interface RS-232C Net Weight 7kg